Home > Products > Lighter manufacturing machine > Full Automatic Flame Size Adjustment Machine

Full Automatic Flame Size Adjustment Machine

option:
Share:
  • Product Description
Overview
Product Attributes

Model No.FT-TH-10

BrandFeituo

StatusNew

Out-of-warranty ServiceVideo Technical Support, Online Support

Where To Provide Local Services (in Which Countries Are There Overseas Service Outlets)None

Showroom Location (in Which Countries Are There Sample Rooms Overseas)None

Video Factory InspectionProvided

Mechanical Test ReportProvided

Marketing TypeNew Product 2020

Core Component Warranty Period1 Year

Core ComponentsPlc, Engine, Bearing, Gearbox, Motor, Pressure Vessel, Gear, Pump

Place Of OriginChina

Warranty Period1 Year

Supply Ability & Additional Information

PackagingWooden box

Productivity10000 per hour

TransportationOcean,Land,Air,Express,Optional

Place of OriginChina

Supply AbilityFactory direct supply

CertificateCE

HS Code84659400

PortShenZhen,GuangZhou

Payment TypeT/T

IncotermFOB

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Wooden box

Feetoo Automation 12

11

22

As the most basic cutting method, flame cutting is also the most widely used cutting method in China. In view of how to grasp the whole cutting process in order to achieve better cutting quality and effect in the process of flame cutting, Feituo industrial control integrates the R & D and sales experience of cutting machines over the years, which is summarized as follows
Preparation before gas cutting
When cutting metal surfaces, rust, dust or oil stain shall be carefully removed. The damaged cutting parts shall be leveled to facilitate heat release halo and slag removal. Never cut on the cement floor, because the cement floor will crack in case of high temperature. The specific requirements before cutting are as follows.
① Check whether the workplace meets the safety requirements, whether the cutting torch, oxygen cylinder, fast cylinder (or B fast generator and flashback preventer), rubber pipe and pressure gauge are normal, and connect the gas cutting equipment according to the operating procedures.
② Before cutting, first level the workpiece and leave a certain gap under the workpiece to facilitate the blowing of iron oxide slag. During cutting, in order to prevent the operator from being burned by splashed iron oxide slag, baffle can be added if necessary.
③ Adjust the oxygen to the required pressure. For the shooting and sucking harmful chanting giant, check whether the harmful chanting giant has the ability of shooting and sucking. The inspection method is as follows: first remove the B fast air inlet hose and bend it, and then open the B shutter and the sub preheating oxygen valve. At this time, put your finger on the acetylene gas pipe joint that is harmful to ice cutting. If your finger feels pumping force and can be adsorbed on the acetylene inlet pipe joint, it shows that the cutting torch has shooting and suction capacity and can be used; On the contrary, it means that the cutting torch is abnormal and cannot be used. It should be checked and repaired.
④ Check the air line by igniting the flame and adjusting the preheated flame properly. Then open the cutting oxygen valve and observe the shape of the cutting oxygen flow (i.e. air line). The air line shall be a straight and clear column with appropriate length. Only in this way can the surface of the workpiece notch be smooth, clean and consistent in width. If the air line is irregular, close all doors and trim the inner surface of the cutting nozzle with a through needle or other tools to make it smooth. Key points of manual gas cutting
During gas operation, first ignite the cutting torch and then adjust the flame. The size of the flame is adjusted according to the thickness of the steel plate, and then the workpiece is preheated and cut.

Fully automatic lighter lighter-The main function of the lighter is to adjust the inflated lighter flame to the same size.
Material: stainless steel + aluminum
Product size: 1.4m*0.8m*1.2m
Voltage: AC220v
Air pressure: 0.6mp
Weight: 245kg
Device model: FT-TH-10
Output: 8000-10000
Operating staff: 1

Process Description
1. Products filled with butane gas must be stored for 12 hours or more before starting once
       Adjust the fire. The face valve of the inflated lighter should not be too tight, as this will lead to
       The flame of the tuned product changes greatly, and it will deform the cotton sheet if it is too tight.
       As a result, the entire lighter is scrapped. Generally, check the height of the face valve to check the flame 1-5 cm
       Is the best. It is particularly noticeable in winter.
2. In principle, the lighter needs to be adjusted twice. After adjusting the fire for the first time, return it
      It needs to be stored for 12 hours or more before the second adjustment.
      Even if the product is stored for a long time, it is not serious that the product becomes fired.


Product Categories : Lighter manufacturing machine

Company Overview
Hunan Feituo Automation Technology Co., Ltd. is a high-tech enterprise focusing on intelligent manufacturing and R & D and sales of automation equipment. The company's main products: lighter kit installation equipment, full-automatic welding machine, full pneumatic control inflator, microcomputer automatic lighter, full-automatic finished product inspection machine, full-automatic face valve assembly machine, full-automatic lighter production line and other automatic equipment.
Company Photos
Production Certification
Home > Products > Lighter manufacturing machine > Full Automatic Flame Size Adjustment Machine
Email to this supplier
  • *Subject:
  • *To:
    Mr. 黄
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send